Electric Motor Bearing Greasing Guide

What Greasing an Electric Motor Bearing Means

Most industrial motors above roughly 10 kW run regreasable bearings: the bearing sits inside a housing with a grease inlet and, on properly built motors, a relief port.

Greasing is not “fill until it comes out somewhere.” It is a measured replenishment: a calculated quantity, at an interval the motor plate or manual defines, with old grease given a path to leave. The quantity formula, the interval, and the procedure each have their own section below.

The Regreasing Quantity Formula

SKF publishes two replenishment formulas: Gp = 0.005 · D · B for grease applied from the bearing side, and Gp = 0.002 · D · B when grease is replenished through holes in the bearing ring. D is the bearing outside diameter and B the bearing width, both in millimeters; the result is grams of grease.

Read that carefully: D is the outside diameter, not the shaft size. A 6210 bearing, for example, has a 90 mm outside diameter and 20 mm width; the bearing-side formula gives 0.005 × 90 × 20 = 9 grams per regrease. If you cannot identify the bearing, open the motor data or read the bearing number from the seal before calculating.

For a worked calculation with your own bearing dimensions, use the bearing lubrication calculator.

Regreasing Intervals: Read the Plate, Not a Chart

There is no universal hour figure for 2-pole versus 4-pole motors. Siemens directs technicians to the lubrication plate on the motor and to regrease at least annually even when running conditions are mild; ABB notes that operating temperature and duty substantially change the interval. The plate exists because bearing size, speed, and grease type move the answer by an order of magnitude.

Where no plate survives, use the manual for the exact frame. Two rules survive across manufacturers: intervals shorten sharply as bearing size grows and as speed rises, and a motor that runs hot needs its interval cut, not its quantity raised.

Grease Selection and the Compatibility Trap

Electric motor bearings commonly run NLGI 2 greases, but the thickener families are not interchangeable. ABB specifies lithium-complex grease for many of its motors and lists particular polyurea greases for some high-speed machines, with an explicit warning not to mix the two families. Polyurea is especially common as the factory fill in sealed-for-life motor bearings.

The practical rule: identify what is in the motor before adding anything. If the existing grease is unknown and cannot be determined, purge thoroughly rather than blend, and stay within one thickener family from then on. The bearing grease types and grades guide covers the families in detail.

Single-Point Lubricators on Motor Bearings

Hard-to-reach motor bearings are the classic case for a single-point lubricator: one bolt-on unit meters grease over months, which removes both the forgotten interval and the over-greasing risk in one move.

Over-Greasing: The Failure You Cause Yourself

Excess grease in the housing churns, heats, and can push into the winding or past shields into the motor. ABB’s guidance is to keep the bearing housing no more than half full of grease and to treat over-greasing as a real damage mechanism in high-speed machines, not an innocent excess. The over-greasing guide covers the symptom set:high running temperatures after regreasing, grease at the drain, and rising vibration.

The Regreasing Procedure

When the motor instructions allow it, regrease while the motor is running or warm, with the relief port open. Wipe the grease inlet clean, pump the calculated quantity slowly, and let the motor run one to two hours afterward so excess grease works out of the relief port, then close it.

If the procedure must be done stopped, ABB’s stopped-motor method divides the amount into portions with a brief full-speed run between them.

Three procedural rules matter more than they look:

StepWhy
Clean the inlet before connectingThe most common contaminant in a motor bearing is what the grease gun pushes in from the fitting
Pump slowly, count gramsFast pumping builds pressure and chases grease past shields instead of into the raceway
Leave the relief port open during the purge runOld grease needs an exit; against a closed port it stays in the housing and churns

When the point is hard to reach or the dose must be repeatable across many motors, metering equipment earns its cost. The automatic greasers for bearings guide compares single-point options, and a pail-mounted pump such as the electric grease pump for 5 gallon buckets feeds workshop-scale motor fleets from one container.

Diagnosing a Motor That Sounds Wrong After Greasing

A motor that is noisier or hotter immediately after regreasing was usually over-filled, not under-filled. Stop, open the relief port, run the purge period fully, and recheck temperature against the motor’s insulation class limits.

If the noise is a dry scraping rather than churn, the grease never reached the raceway: check for a blocked feed path, a hardened plug in the housing, or an inlet fitting that accepts grease but does not pass it. Persistent starvation has its own symptom ladder in the bearing grease starvation guide.

Sealed-for-life bearings sit outside this procedure by design. When they reach end of life, replacement is the service action; the self-lubricating bearings guide explains what that design trades away.

Free calculator

Bearing lubrication calculator

Initial fill, relubrication amount, interval and annual consumption from the bearing type, dimensions, speed, temperature, environment and load.

Frequently Asked Questions

How much grease does an electric motor bearing take?

Use SKF’s replenishment formula: 0.005 × D × B grams from the bearing side, or 0.002 × D × B through ring holes, with D the bearing outside diameter and B its width in millimeters. Apply exactly that quantity, not more.

How often should motor bearings be greased?

Follow the lubrication plate or the motor manual; Siemens sets annual regreasing as the minimum even in mild duty. Intervals shorten sharply with larger bearings, higher speed, and higher running temperature.

Can polyurea and lithium grease be mixed in a motor?

No. ABB explicitly warns against mixing polyurea with lithium-complex grease. Identify the existing thickener first, and if it is unknown, purge rather than blend.

Should the motor be running when you grease it?

Yes, where the motor instructions allow it: running warm with the relief port open lets old grease escape. ABB advises a one to two hour purge run afterwards. If stopped regreasing is required, divide the quantity with brief full-speed runs between portions.

Why is the motor hotter after greasing?

Almost always excess quantity churning in the housing. Open the relief port, complete the purge run, and verify the housing is no more than half full before the next cycle.

What happens if a motor bearing gets no grease at all?

The lubricating film thins until metal contact begins; the failure ladder from first dry noise to spalling is described in the bearing grease starvation guide. Caught early, one correct regrease reverses it.

Related: lubrication preventive maintenance checklist

MY
Written by
Founder & Chief Engineer, IsoHiTech
Mike Yao has engineered centralized lubrication systems since 2006 — from single-line machine-tool systems to progressive and dual-line systems for steel, mining and heavy equipment — and today leads application engineering at IsoHiTech Lubrication Systems, a manufacturer founded in 2023 based in Nanjing, China.