Lincoln PMA 2 Piston Pump 30-60 mm3

Aftermarket piston pump replacing the Lincoln PMA 2. 30 or 60 mm3 per outlet per stroke, 1-6 outlets, 50 bar, 24 V DC to 230 V AC, IP65, option N cycle sensor.

What the PMA 2 Is

The PMA 2 is a solenoid-operated progressive piston pump designed for oil lubrication in small to medium centralized systems. It delivers a fixed, repeatable volume per outlet per stroke, making it suitable for applications where consistent metering matters. The pump body supports one to six outlets, allowing a single unit to serve multiple lubrication points without air pockets in the delivery path.

Lincoln and SKF are trademarks of their respective owners.

This is an aftermarket pump, not manufactured, sponsored, or endorsed by SKF.

PMA 2 designations are for cross-reference identification only.

The PMA 2 uses an electric solenoid to drive a piston, pushing oil through individual outlets on each stroke. It is a multi-outlet oil pump intended for use with progressive dividers or direct lubrication points where per-outlet metering is required.

Specifications

Pump typeSolenoid-operated progressive piston pump
Output volume30 or 60 mm3 per outlet per stroke
Number of outlets1 to 6
Max operating pressure50 bar, depending on number of outlets
Voltages24 V DC, 120 V AC, 230 V AC
Max stroke rate5 cycles per second per catalog; secondary documentation lists 4 Hz continuous and 5 Hz intermittent with 5 min on/off cycling, confirm against documentation
Protection classIP65
Inlet portG1/4
Outlet connection6 mm tubing
Filtration requirement30 micron
Max filling pressure (inlet side)0.5 bar
Option NIntegrated proximity switch for cycle monitoring

How the Solenoid Pump Works

The solenoid drives a piston through a short, controlled stroke each time it is energized. Each stroke displaces a fixed volume of oil from the piston chamber to the connected outlet. Because the piston and cylinder geometry determine the metered amount, the volume per outlet per stroke remains consistent across operating cycles.

Total pump output is not a single fixed number. It scales with the number of outlets and the stroke rate. A pump configured for 60 mm3 per outlet per stroke will move more oil as stroke frequency increases, but the per-outlet metering stays the same on every stroke.

Optional cycle monitoring is available through option N, an integrated proximity switch. This switch detects piston movement and can signal a control system when strokes are missed or interrupted. It provides a simple way to confirm that the pump is cycling as expected during operation.

Outlets, Volume, and Pressure

The phrase “per outlet per stroke” means each outlet receives the specified volume on every piston stroke. For example, a 4-outlet pump set to 60 mm3 per outlet per stroke running at 4 cycles per second moves 4 x 60 x 4 = 960 mm3/sec total across all outlets. Each individual outlet still receives only 60 mm3 per stroke.

Available pressure per line decreases as the number of outlets increases. The 50 bar maximum is a ceiling that depends on outlet count and system configuration. Fewer outlets generally allow higher pressure per line, while more outlets split the available output across more points.

When feeding downstream progressive dividers, use a maximum of 2 outlets. This keeps flow concentrated so the divider receives enough volume per stroke to operate reliably. Using more than 2 outlets for divider feed can starve the divider and cause inconsistent cycling.

Tubing Length and Nozzle Arrangement

Main line tubing length limits depend on the volume setting. The 60 mm3 version supports steel tubing up to 6 m or plastic tubing up to 3 m. The 30 mm3 version supports steel tubing up to 3 m or plastic tubing up to 1.5 m. These limits apply to the main line from pump outlet to lubrication point or divider.

Plastic tubing installations require inserts at compression fittings to prevent the tube from collapsing under pressure. Steel tubing does not need inserts but must be bent and routed carefully to avoid kinks. Keep lines as short as practical within the stated limits.

At the point of use, short nozzles or mist jets can be fitted to direct oil precisely where needed. Nozzle selection should match the lubrication point geometry and the oil viscosity in use.

Related Parts

For point-of-use oil delivery, pair the PMA 2 with squirt nozzles and compatible lubrication tubing sized for 6 mm outlets.

Learn how these pumps fit into centralized lubrication systems, and request pricing through the quotation form.

Frequently Asked Questions

What is the PMA 2 pump?

The PMA 2 is a solenoid-operated progressive piston pump for oil. It delivers fixed volume per outlet per stroke to multiple points.

Should I choose 30 or 60 mm3 per outlet per stroke?

Choose 60 mm3 for longer lines or higher flow needs. Choose 30 mm3 for shorter lines or smaller metered doses.

How does outlet count affect pressure?

More outlets split the pump output across more lines. Maximum pressure of 50 bar depends on outlet count.

What voltage options are available?

The PMA 2 is available in 24 V DC. It also comes in 120 V AC and 230 V AC.

Can the PMA 2 feed progressive dividers?

Yes, but use a maximum of 2 outlets. This keeps divider flow strong enough for reliable cycling.

What are the tubing length limits?

For 60 mm3, steel line is 6 m and plastic is 3 m. For 30 mm3, steel is 3 m and plastic is 1.5 m.

Should I use plastic or steel tubing?

Steel allows longer main line runs than plastic. Plastic requires inserts at compression fittings to prevent collapse.

What does option N do?

Option N adds an integrated proximity switch for cycle monitoring. It detects piston movement and signals missed or interrupted strokes.

What filtration is required for the oil?

Use a 30 micron filter on the inlet side. Cleaner oil protects the piston and outlet metering accuracy.

How do I order or get support?

IsoHiTech Lubrication Systems, founded in 2023, engineering since 2006, builds and supports every unit. Email inquiry@isohitech.com for specifications and a quotation.

Use the config code structure PMA 2 – [number of outlets] – [volume per stroke] – [voltage] – [options]. You can also request help through the quotation form.