The DLX multiply lubrication injector (33000 series) is a multi-outlet positive displacement injector (PDI) for cyclic central oil and soft-grease systems. One body feeds 2, 3, 4, or 5 lubrication points; each outlet can be set to a different discharge code so one machine header covers bearings with unlike dose requirements.
On each cycle the system pressurizes the main line—each outlet meters its preset volume—then relieves pressure so injectors recharge from supply. Typical plant working pressure is 1.75–3.5 MPa (17.5–35 bar). Discharge per outlet is selected from 0.03 / 0.06 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 ml/cycle. Unused ports may be closed with a special plug (code 0)—unlike progressive blocks, this is allowed on PDI multiply units.
Used on printing, plastics, packaging, and machine-tool lines where several nearby points share one cyclic pump. System hub: positive injector systems · DLX single injector · injection lubrication system · lubrication injectors.
- Parameter
- Product Video
DLX Multiply Injector — Discharge Size Codes
| Code | Mark | Discharge (ml/cyc) | Typical use |
|---|---|---|---|
| A / 03 | 03 | 0.03 | Fine oil film, small bearings |
| B / 06 | 06 | 0.06 | Light machine-tool spindles |
| C / 10 | 10 | 0.10 | Standard small point |
| D / 20 | 20 | 0.20 | Medium slide / cam |
| E / 30 | 30 | 0.30 | Heavier way cover |
| F / 40 | 40 | 0.40 | Packaging line roll |
| G / 50 | 50 | 0.50 | Maximum multiply dose |
| 0 | Plug | — | Blocked unused outlet |
Part Number Example
33000T-20/30/40/50 means:
- 33000 — multiply injector product family
- T — supplied with adaptors and compression sleeve kit
- 20/30/40/50 — left-to-right outlet discharge: 0.2 / 0.3 / 0.4 / 0.5 ml/cycle on a 4-outlet body
Order each outlet code independently when building the BOM. IsoHiTech confirms port orientation on quotation drawing.
Operating Limits
| Parameter | Value |
|---|---|
| Outlets per body | 2 / 3 / 4 / 5 |
| System pressure class | 1.75–3.5 MPa typical working |
| Max operating pressure | ~5 MPa (confirm on datasheet) |
| Oil viscosity | ISO #20 – #1500 |
| Soft grease | NLGI #000 – #00 (semi-fluid only) |
| Seals | Viton |
| Secondary tubing | 4 mm typical to each point |
DLX Multiply Injectors in Cyclic PDI Systems
How Multiply PDI Metering Works
Unlike progressive divider blocks that meter in strict sequence, multiply injectors act in parallel on the same pressure rise. When the pump builds line pressure:
- Each outlet’s internal piston reaches its start pressure and discharges its fixed preset volume.
- Check valves hold dose at the bearing while the line remains pressurized.
- When the controller vents or stops the pump, pressure falls and all chambers refill from the main header.
- The next timed cycle repeats—delivering periodic oil or soft grease without manual greasing.
Because each outlet has its own size code, a four-outlet multiply block can feed one 0.2 ml cam, one 0.3 ml slide, and two 0.5 ml rolls from a single mounted body—reducing header clutter versus four separate single injectors.
Typical System Layout
- Pump + timer — cyclic oil pump or SM pneumatic lubricator for soft-grease PDI.
- Main supply line — sized for peak simultaneous injector demand at 1.75–3.5 MPa.
- 33000 multiply injector(s) — mounted near the machine zone; 2–5 outlets per body.
- 4 mm branch lines — to each bearing, chain, or gear with compression fittings.
- Relief / vent — ensures injectors recharge; cycle time set in PLC or mechanical timer.
Multiply vs Single DLX vs SL1 / SL32
| Device | Outlets | Pressure | Media | When to use |
|---|---|---|---|---|
| 33000 multiply (this page) | 2–5 per body | 1.75–3.5 MPa | Oil; NLGI #000–#00 | Several nearby points, different ml/cyc each |
| 34000 single DLX | 1 | 1.75–3.5 MPa | Oil cyclic | One point per body; simplest PDI |
| SL1 | 1 (manifold optional) | 6.5–20 MPa | Oil; semi-fluid grease | Higher pressure grease PDI |
| SL32 | 1–12 manifold | 8–24 MPa | Grease | Multi-point grease, factory block |
| DJF progressive | 3–20 sequential | 25 MPa | Oil / NLGI #000–#2 | Series logic + cycle pin monitor |
Five-Step Selection
- List points — count bearings and required ml/cycle from OEM chart.
- Group by location — points within ~1 m can share one multiply body; distant points need another header or single injectors.
- Assign discharge codes — pick 03–50 per outlet; plug unused ports with code 0.
- Confirm viscosity — oil ISO #20–1500 within pump range; soft grease NLGI #000–#00 only.
- Size pump cycle — ensure pump reaches operating pressure fast enough for all outlets to fire before vent.
Installation & Commissioning
- Mount with flow arrow correct; tighten compression sleeves without crushing 4 mm tube.
- Fill system with specified clean oil or soft grease—no mixed grades.
- Run several pressure cycles; verify each outlet delivers grease/oil at the furthest point.
- Label outlet positions with size codes for future service.
- On soft-grease systems, confirm ambient temperature allows NLGI #00 to flow in secondary lines.
Troubleshooting
| Symptom | Likely cause | Action |
|---|---|---|
| One outlet never fires | Wrong code plug, blocked port, reversed install | Verify part number suffix; clear line; check arrow |
| All outlets weak | Pump below 1.75 MPa, air lock, wrong viscosity | Adjust pump; bleed air; confirm ISO grade |
| Over-delivery at one port | Wrong size code after field swap | Restore BOM suffix (e.g. 20 vs 50) |
| Grease stiff in winter | NLGI too thick for PDI multiply | Drop to #000/#00 or heat trace lines |
Industry Applications
- Printing — roll bearings, chains, cam boxes (oil PDI)
- Plastics — injector pins, tie-bar slides (multiply 3–5 outlets)
- Packaging — multiple cam shafts on one header
- Machine tools — way covers and ball screws with mixed doses
Related pumps: 2 kg oil pump, 4 kg oil pump, FS grease pump (soft grease PDI only when viscosity matches).
Before you buy: read our grease fitting types guide.
A multiply injector is a multi-outlet PDI body that meters a fixed dose to 2–5 points per cycle. Each outlet has its own discharge code (0.03–0.5 ml/cyc). The DLX 33000 series is used on cyclic oil and soft-grease central systems at 1.75–3.5 MPa.
The single DLX (34000) feeds one point per body. Multiply (33000) feeds 2–5 points from one block with independent size codes per port—example: 33000T-20/30/40/50.
Yes. Order suffix lists left-to-right codes (e.g. 20/30/40/50 = 0.2 / 0.3 / 0.4 / 0.5 ml/cycle). Unused outlets use plug code 0.
Oil ISO #20 – #1500 for standard cyclic oil PDI. Soft grease NLGI #000 – #00 only—standard NLGI #1–#2 grease requires high-pressure injectors such as SL1 or progressive blocks.
Typical system pressure 1.75–3.5 MPa (17.5–35 bar). Do not exceed injector rated maximum (~5 MPa class)—match pump relief and hose rating.
Yes on multiply PDI—use the factory plug (code 0). This differs from progressive divider blocks where plugging outlets stops the chain.
Use multiply PDI for cyclic oil/soft grease with parallel dosing on pressure rise. Use progressive blocks when you need sequential monitoring, higher pressure (25 MPa), or standard NLGI #1–#2 grease.
Small cyclic oil pumps, pneumatic SM lubricators, or plant controllers on positive injector systems—size for simultaneous outlet discharge.