Multiply Injector

Multiply Injector

The DLX multiply lubrication injector (33000 series) is a multi-outlet positive displacement injector (PDI) for cyclic central oil and soft-grease systems. One body feeds 2, 3, 4, or 5 lubrication points; each outlet can be set to a different discharge code so one machine header covers bearings with unlike dose requirements.

On each cycle the system pressurizes the main line—each outlet meters its preset volume—then relieves pressure so injectors recharge from supply. Typical plant working pressure is 1.75–3.5 MPa (17.5–35 bar). Discharge per outlet is selected from 0.03 / 0.06 / 0.1 / 0.2 / 0.3 / 0.4 / 0.5 ml/cycle. Unused ports may be closed with a special plug (code 0)—unlike progressive blocks, this is allowed on PDI multiply units.

Used on printing, plastics, packaging, and machine-tool lines where several nearby points share one cyclic pump. System hub: positive injector systems · DLX single injector · injection lubrication system · lubrication injectors.

DLX Multiply Injector — Discharge Size Codes

CodeMarkDischarge (ml/cyc)Typical use
A / 03030.03Fine oil film, small bearings
B / 06060.06Light machine-tool spindles
C / 10100.10Standard small point
D / 20200.20Medium slide / cam
E / 30300.30Heavier way cover
F / 40400.40Packaging line roll
G / 50500.50Maximum multiply dose
0Plug—Blocked unused outlet

Part Number Example

33000T-20/30/40/50 means:

  • 33000 — multiply injector product family
  • T — supplied with adaptors and compression sleeve kit
  • 20/30/40/50 — left-to-right outlet discharge: 0.2 / 0.3 / 0.4 / 0.5 ml/cycle on a 4-outlet body

Order each outlet code independently when building the BOM. IsoHiTech confirms port orientation on quotation drawing.

Operating Limits

ParameterValue
Outlets per body2 / 3 / 4 / 5
System pressure class1.75–3.5 MPa typical working
Max operating pressure~5 MPa (confirm on datasheet)
Oil viscosityISO #20 – #1500
Soft greaseNLGI #000 – #00 (semi-fluid only)
SealsViton
Secondary tubing4 mm typical to each point

DLX Multiply Injectors in Cyclic PDI Systems

How Multiply PDI Metering Works

Unlike progressive divider blocks that meter in strict sequence, multiply injectors act in parallel on the same pressure rise. When the pump builds line pressure:

  1. Each outlet’s internal piston reaches its start pressure and discharges its fixed preset volume.
  2. Check valves hold dose at the bearing while the line remains pressurized.
  3. When the controller vents or stops the pump, pressure falls and all chambers refill from the main header.
  4. The next timed cycle repeats—delivering periodic oil or soft grease without manual greasing.

Because each outlet has its own size code, a four-outlet multiply block can feed one 0.2 ml cam, one 0.3 ml slide, and two 0.5 ml rolls from a single mounted body—reducing header clutter versus four separate single injectors.

Typical System Layout

  1. Pump + timer — cyclic oil pump or SM pneumatic lubricator for soft-grease PDI.
  2. Main supply line — sized for peak simultaneous injector demand at 1.75–3.5 MPa.
  3. 33000 multiply injector(s) — mounted near the machine zone; 2–5 outlets per body.
  4. 4 mm branch lines — to each bearing, chain, or gear with compression fittings.
  5. Relief / vent — ensures injectors recharge; cycle time set in PLC or mechanical timer.

Multiply vs Single DLX vs SL1 / SL32

DeviceOutletsPressureMediaWhen to use
33000 multiply (this page)2–5 per body1.75–3.5 MPaOil; NLGI #000–#00Several nearby points, different ml/cyc each
34000 single DLX11.75–3.5 MPaOil cyclicOne point per body; simplest PDI
SL11 (manifold optional)6.5–20 MPaOil; semi-fluid greaseHigher pressure grease PDI
SL321–12 manifold8–24 MPaGreaseMulti-point grease, factory block
DJF progressive3–20 sequential25 MPaOil / NLGI #000–#2Series logic + cycle pin monitor

Five-Step Selection

  1. List points — count bearings and required ml/cycle from OEM chart.
  2. Group by location — points within ~1 m can share one multiply body; distant points need another header or single injectors.
  3. Assign discharge codes — pick 03–50 per outlet; plug unused ports with code 0.
  4. Confirm viscosity — oil ISO #20–1500 within pump range; soft grease NLGI #000–#00 only.
  5. Size pump cycle — ensure pump reaches operating pressure fast enough for all outlets to fire before vent.

Installation & Commissioning

  • Mount with flow arrow correct; tighten compression sleeves without crushing 4 mm tube.
  • Fill system with specified clean oil or soft grease—no mixed grades.
  • Run several pressure cycles; verify each outlet delivers grease/oil at the furthest point.
  • Label outlet positions with size codes for future service.
  • On soft-grease systems, confirm ambient temperature allows NLGI #00 to flow in secondary lines.

Troubleshooting

SymptomLikely causeAction
One outlet never firesWrong code plug, blocked port, reversed installVerify part number suffix; clear line; check arrow
All outlets weakPump below 1.75 MPa, air lock, wrong viscosityAdjust pump; bleed air; confirm ISO grade
Over-delivery at one portWrong size code after field swapRestore BOM suffix (e.g. 20 vs 50)
Grease stiff in winterNLGI too thick for PDI multiplyDrop to #000/#00 or heat trace lines

Industry Applications

  • Printing — roll bearings, chains, cam boxes (oil PDI)
  • Plastics — injector pins, tie-bar slides (multiply 3–5 outlets)
  • Packaging — multiple cam shafts on one header
  • Machine tools — way covers and ball screws with mixed doses

Related pumps: 2 kg oil pump, 4 kg oil pump, FS grease pump (soft grease PDI only when viscosity matches).

Before you buy: read our grease fitting types guide.

What is a multiply lubrication injector?

A multiply injector is a multi-outlet PDI body that meters a fixed dose to 2–5 points per cycle. Each outlet has its own discharge code (0.03–0.5 ml/cyc). The DLX 33000 series is used on cyclic oil and soft-grease central systems at 1.75–3.5 MPa.

How does DLX multiply differ from a single injector?

The single DLX (34000) feeds one point per body. Multiply (33000) feeds 2–5 points from one block with independent size codes per port—example: 33000T-20/30/40/50.

Can each outlet have a different discharge?

Yes. Order suffix lists left-to-right codes (e.g. 20/30/40/50 = 0.2 / 0.3 / 0.4 / 0.5 ml/cycle). Unused outlets use plug code 0.

What lubricants are compatible?

Oil ISO #20 – #1500 for standard cyclic oil PDI. Soft grease NLGI #000 – #00 only—standard NLGI #1–#2 grease requires high-pressure injectors such as SL1 or progressive blocks.

What is the working pressure range?

Typical system pressure 1.75–3.5 MPa (17.5–35 bar). Do not exceed injector rated maximum (~5 MPa class)—match pump relief and hose rating.

Can I block an unused outlet?

Yes on multiply PDI—use the factory plug (code 0). This differs from progressive divider blocks where plugging outlets stops the chain.

Multiply injector or progressive block?

Use multiply PDI for cyclic oil/soft grease with parallel dosing on pressure rise. Use progressive blocks when you need sequential monitoring, higher pressure (25 MPa), or standard NLGI #1–#2 grease.

What pumps pair with multiply injectors?

Small cyclic oil pumps, pneumatic SM lubricators, or plant controllers on positive injector systems—size for simultaneous outlet discharge.