Grease Transfer Pumps

A grease transfer pump has one job: move thick grease from where it is stored — drum, keg, pail or 5-gallon bucket — to where it is used: a machine reservoir, a central system tank, or a dispensing point. It is not the pump that meters grease to bearings; it is the one that empties the container. Every unit on this page is cataloged for that duty.

Three drives do the work. Air motors run the SUREMATIC 18:1 class with 8 cc per stroke from a 2-liter follower. Electric units — DZG at 25 MPa and 6 ml/min on 220/380V, the Y6020, the Bijur DS at 15 MPa and 25 ml/min — cover powered transfer where compressed air is absent. Hand-operated units move grease by lever, slowly, with nothing to power at all.

Where a unit also sits on the air, electric or bucket-pump pages for its drive class, the table says so; this page holds the transfer-duty view.

Transfer Duty by Drive

DriveUnitStated spec
AirSM Type SUREMATIC, Sure 88118:1 ratio, 2-liter, 8 cc/stroke
ElectricDZG electric, Y6020, Bijur DSDZG 25 MPa 6 ml/min 220/380V; DS 15 MPa 25 ml/min
Bucket-mount electric5-gallon bucket pump, Bucket pump 120V/12V/18VMounted on the pail they empty
ManualHand-operated transfer pumpLever drive, no power needed
High-viscosity general25 kg pneumatic grease pumpPneumatic, high-viscosity class

The Transfer Catalog

Catalog pageStated spec
SM Type SUREMATIC air pump18:1, 2-liter, 8 cc/stroke
Sure 881 air pumpAir-operated transfer class
DZG electric grease pump25 MPa, 6 ml/min, 220/380V
Y6020 electric grease pumpY6020 powered transfer
Bijur DS grease pump15 MPa, 25 ml/min, SLR & progressive
Electric pump for 5-gallon bucketPortable workshop transfer
Electric bucket pump120V/12V/18V
Hand-operated transfer pumpManual lever transfer
Industrial grease transfer pumpPneumatic & electric, high-viscosity

The drive-class catalogs continue under air grease pumps, electric grease pumps and bucket pumps; the full pump range under grease pumps.

Grease Transfer Pump FAQ

Transfer pump or lubrication pump — what is the difference?

Duty, not hardware. A transfer pump empties containers: drum to reservoir, bucket to machine tank. A lubrication pump feeds measured grease to bearings through lines and meter units. Several pumps here do both jobs — the DZG and DS run at pressures that serve progressive lines — but they are cataloged for transfer because that is the first question buyers ask of them.

Why does the SUREMATIC quote a ratio?

The 18:1 is air-to-grease pressure multiplication: 100 psi of air in, roughly 1800 psi of grease out — the ratio stated in the title of the SM Type unit. That is what lets an air motor push NLGI-2 grease through a hose stiff with cold, at 8 cc per stroke from its 2-liter container.

What does 6 ml/min versus 25 ml/min mean in practice?

Filling speed against line duty. The DZG’s 6 ml/min at 25 MPa is a high-pressure, low-volume profile — it can push through resistance. The DS at 15 MPa and 25 ml/min moves roughly four times the volume per minute at lower pressure. Refilling a reservoir through an open port favors volume; pushing through a long hose favors pressure.

Is a bucket-mount pump a real transfer pump?

Yes — it is transfer in its most direct form. The 5-gallon units and the 120V/12V/18V bucket pump thread onto the pail the grease ships in, so the container is the reservoir. There is no decanting, no drum tapping; the pump lifts grease straight from the original package.

Which drive should a workshop without compressed air choose?

Electric or hand. The DZG, Y6020 and bucket pumps run on mains or battery voltages; the hand-operated lever pump needs nothing but arm effort and moves grease at a pace that suits occasional machine-top-ups. Send the grease grade and container size through the contact page and the return matches a unit to both.

Showing all 6 results