What the Pump Does
This is the compact axis of a two-page pump pair. The DC-110×2 is a 2 L unit intended for one machine or a small group of points. Where the point count multiplies, or where a controller is wanted at the pump, the 6L lubrication pump covers the larger reservoir family.
The pump moves oil from its own reservoir to the points through the metering hardware already fitted on the machine. Actual delivery shifts with oil viscosity and back pressure, so size with margin.
Supply is 220 V AC and power draw is 20 W. For orientation, the central lubrication system guide explains the system types and where each pump family sits.
Declared Specifications
| Model | DC-110×2 |
| Part number, no controller | 20121 |
| Part number, SLR systems | 20121D |
| Part number, PDI systems | 20124 |
| Part number, PDI systems, second variant | 20124D |
| Rated delivery | 108 ml/min |
| Working pressure | 2.5 MPa |
| Oil viscosity range | grades 20 to 320 |
| Supply | 220 V AC |
| Power | 20 W |
| Reservoir | 2 L, plastic standard, metal on request |
| Outlet threads | M8x1, M10x1, M12x1, NPT 1/8 |
Controller and System Options
The part number follows the metering hardware on the machine.
Part 20121 runs whenever power is applied. It suits a machine whose own control already switches the pump.
Part 20121D suits single-line resistance systems. Oil is pushed through one line and each point carries a resistance fitting that proportions flow.
Parts 20124 and 20124D feed injector systems, known as PDI. Here the pump charges one line and each injector meters its own shot to its point, so the pump must develop pressure reliably.
If the difference between resistance and injector layouts is not settled, read the central lubrication system guide first. Choosing the pump before the system type is the most common ordering mistake.
Outlet and Reservoir Choices
Outlet threads are M8x1, M10x1, M12x1 and NPT 1/8. State the thread when ordering. Match the fittings already on the machine so the pump connects without adapters and extra weeping points.
The reservoir is 2 L and plastic as standard. Metal is on request; state it when ordering. How long 2 L lasts depends on the number of points and the cycle: more points, or a shorter interval, empties it sooner.
All four part numbers share the same delivery, pressure, supply, power and reservoir; only the control behaviour differs. See the wider oil lubrication pumps range if the size is wrong once the point count is final.
Sizing Against the 6L Family
Stay with the DC-110×2 when the layout is one machine or a small group of points, when 2 L of oil is enough for a sensible fill interval, and when the machine control or a simple powered run is acceptable.
Move to the 6L family when points multiply, when a longer interval between fills matters more than body size, or when a controller is wanted at the pump rather than in the machine cabinet.
Remember that 108 ml/min is nominal: if the calculated demand sits close to it at your viscosity, step up rather than hope, because undersizing leaves the far points dry.
Installation Pointers
Mount the pump close to the points it serves. Short lines prime faster and make weeping easier to reach.
Prime the pump and lines before the first run. Prime at the outlet and let the system fill from there.
After the first run, check for weeping at every outlet and at each joint.
Keep the reservoir capped and filled with filtered oil. Use oil within grades 20 to 320 and keep to one grade; mixing grades changes the flow at every point.
Contact the team with the point list, line lengths and oil grade, and the sizing can be checked against the 6L family.
Frequently Asked Questions
What does the 108 ml/min rating mean?
It is nominal delivery at reference conditions. Real delivery shifts with viscosity and back pressure, so size with margin.
Does the pump include a controller?
Part 20121 has none and runs when powered. The other variants match specific system types.
Can it pump grease?
No. This unit is for oil within grades 20 to 320.
Which viscosity grades are allowed?
Grades 20 to 320. Stay within that band and keep one grade through the fill cycle.
How do I choose the outlet thread?
Match the fittings already on the machine; contact the team if adapters are needed.
Is the reservoir plastic or metal?
Plastic is standard. Metal is available on request; state it when ordering.
How long does a 2 L reservoir last?
It depends on point count and cycle. More points empty it sooner.
When should I choose the 6L family instead?
When points multiply, fills should be less frequent, or a controller is wanted at the pump.
What maintenance does the pump need?
Keep the reservoir capped and filled with filtered oil, and check for weeping at the outlets.
How do I get specifications and a quotation?
IsoHiTech Lubrication Systems, founded in 2023, engineering since 2006, builds and supports every unit. Email inquiry@isohitech.com for specifications and a quotation.