What This Insert Does
This internal brass sleeve presses into 12 mm O.D. x 9 mm I.D. tube and holds the bore round while the ferrule bites down. The stiff 1.5 mm wall is the point of the part: on medium-bore copper, brass and rigid nylon lines, an unsupported tube ovalises under ferrule load and the joint starts to weep. With the insert in place, the tube keeps its circular section and the ferrule seats against a firm backing rather than a collapsing wall. The insert suits hydraulic and centralized lubrication lines carrying mineral oils and synthetic esters, and it is equally at home in pilot lines, divider feeds and short manifold runs where tube stiffness matters more than flow area.
Technical Specifications
Dimensions below are nominal with the working tolerances called out. Confirm tube bore and fluid before ordering.
| Property | Value |
| Insert outer diameter (fits tube bore) | 9 mm (plus/minus 0.03 mm) |
| Fits tube outer diameter | 12 mm (tolerance 0 to minus 0.05 mm) |
| Support wall | 1.5 mm (plus/minus 0.02 mm) |
| Material | C36000 free-cutting brass |
| Working pressure of assembly | 850 psi at 20°C, 650 psi at 100°C |
| Temperature | -30°C to 180°C continuous |
| Compatible fluids | mineral oils 32 to 68 cSt, synthetic esters |
Sizing and Fit in the Insert Ladder
The insert outer diameter must equal the tube bore exactly. A loose insert lets the tube ovalise under the ferrule, and the joint will not hold. This size sits between the smaller pilot-line inserts and the 16 mm x 12 mm step-up insert, so it is the natural choice when a line steps up from light pilot tubing but does not yet need the larger bore. Pair it with ferrules and sleeves matched to the same tube size, and keep the tube cut square so the insert enters without distortion. If the tube wall is thin or the run is long, check that the wall thickness can carry the ferrule load before assembly.
Installation Steps
- Cut the tube square and deburr the edge; a light 0.2-0.3 mm chamfer helps the ferrule seat.
- Push the insert home into the tube bore until it bottoms evenly.
- Slide the nut and ferrule onto the tube.
- Tighten to specification rather than by feel.
- Check for weeping under working pressure.
- Re-check the joint after the first thermal cycle.
Tolerances, Torque and Weeping Joints
Burrs left on the tube edge score the ferrule seat and give fluid a path out. A cocked insert opens a spiral path for fluid along the tube wall, which shows up as a weeping joint long before the fitting fails outright. Over-tightening crushes the tube against the insert and work-hardens the ferrule until it cracks. Tighten to specification, not to feel, and inspect the full insert range when a line needs a different bore. Where duty exceeds what a tube assembly can carry, move to steel-braided hose instead of pushing the tube joint harder.
What Is Supplied
Machined C36000 brass inserts to the tolerances above. Confirm tube dimensions and fluid when ordering, then request a quote for the quantities you need.
Frequently Asked Questions
Should the insert outer diameter match the tube bore exactly?
Yes. The insert outer diameter must equal the tube bore exactly. A loose fit lets the tube ovalise under the ferrule.
What does the 1.5 mm support wall do?
It keeps the tube round under ferrule load. The stiff wall stops the bore collapsing as the ferrule bites down.
Does this insert replace the compression ferrule?
No. The insert supports the tube from inside. The ferrule still grips the tube outer surface and makes the seal.
Why does the pressure value drop from 850 psi to 650 psi at 100°C?
Brass softens and the tube relaxes as temperature rises. The lower figure reflects the reduced assembly strength at 100°C.
Which fluids is the brass body suited to?
Mineral oils in the 32 to 68 cSt range and synthetic esters. Confirm your fluid before ordering.
Why does a cocked insert cause a weeping joint?
A cocked insert leaves a spiral gap along the tube wall. Fluid travels that path and shows as weeping under pressure.
Can the insert be reused after disassembly?
Inspect it first. A deformed or scored insert should be replaced rather than refitted.
How do I know if my tube wall needs support?
Thin walls and long unsupported runs are the usual signs. If the tube ovalises by hand, it needs an insert.
Can tightening by feel damage the joint?
Yes. Over-tightening crushes the tube against the insert and work-hardens the ferrule until it cracks.
Can IsoHiTech confirm tolerances before ordering?
Yes. IsoHiTech Lubrication Systems, founded in 2023, engineering since 2006, holds dimensional tolerances on every size. Send your tube and fluid details to inquiry@isohitech.com or via the quote page for confirmation.