Brass Tube Insert Stiffener | CDA 360, 5-15 mm OD

CDA 360 brass tube insert stiffeners (5×3, 6×4, 15×12 mm) reinforce nylon, PU, PTFE and TPR tubing for dependable compression fitting joints to 300 PSI.

Product Overview

These brass tube insert stiffeners from IsoHiTech Lubrication Systems reinforce plastic tubing ends for compression fitting assembly. When nut and ferrule tighten onto soft tubing – nylon (PA), polyurethane (PU), PTFE, or TPR – the wall can deform or crush without support; the insert keeps the tube round so the ferrule seals on a stable surface.

The material is CDA 360 free-cutting brass (CuZn39Pb3 / CW614N, ASTM B16 designation). Three sizes: 5 x 3 mm for micro-lubrication, 6 x 4 mm for standard industrial systems, 15 x 12 mm for heavy-duty main lines.

Dimensions

Parameter5 x 3 mm6 x 4 mm15 x 12 mm
Outer diameter5.00 mm +0.00/-0.056.00 mm +0.00/-0.0515.00 mm +0.00/-0.05
Inner diameter3.00 mm ±0.034.00 mm ±0.0312.00 mm ±0.03
Wall thickness1.00 mm ±0.051.00 mm ±0.051.50 mm ±0.05
Standard lengths10, 15, 20 mm10, 15, 20, 25, 30 mm20, 25, 30, 40 mm
Unit weight (approx.)2-3 g3-5 g12-18 g

Performance Ratings

Working pressure: 300 PSI (21 bar) – an assembly rating covering insert, soft tube, ferrule, and fitting body together, not the brass alone. Operating temperature: -29°C to +149°C. Concentricity and surface finish confirm at order.

Compatible Tubing

Tubing MaterialMax PressureNotes
Nylon PA66 / PA12300 PSIStandard for centralized lubrication lines
Polyurethane (PU)250 PSIFlexible routing, abrasion resistant
PTFE200 PSIChemical and temperature resistance
TPR / TPE150 PSILow-pressure and return lines

Pair them with our polyamide lubrication tubing and matching compression bushings; the full range is under tubing inserts.

Applications by Size

5 x 3 mm suits micro-lubrication circuits and instrument bearings. 6 x 4 mm is the most common industrial size – slideways, ball screws, single-line lubrication networks. 15 x 12 mm serves heavy main distribution lines on machinery and marine equipment.

Installation

  1. Cut the tube square with a tube cutter, remove all burrs, and clean the end.
  2. Match the insert to the tube OD and ID exactly – never force an oversized insert or use an undersized one.
  3. Push the insert in until its face is flush with the tube end (±0.5 mm).
  4. Slide on the nut and ferrule; tighten to the fitting manufacturer’s torque with a backup wrench on the body.
  5. Pressurize the line to 1.5x working pressure and check the joint for leaks before commissioning.

Limitations to Know Before Ordering

  • Metal tubing needs no insert – copper, brass, and steel tubes are rigid enough, and an insert can prevent correct ferrule bite.
  • These inserts are for compression fittings only – push-in fittings grip the tube with a collet and O-ring instead of a ferrule.
  • Do not reuse an insert showing deformation, scoring, or pitting; the press fit depends on full wall integrity.

Custom Options

Non-standard lengths and stainless steel 316 inserts (marine/chemical use) are available on request, as are bulk and private-label packaging.

For custom specifications or volume pricing, contact us for a quote or email inquiry@isohitech.com.

Unsure which size matches your tube? Measure the tube ID and ask for a sizing quotation. See also our grease fitting types guide.

Frequently Asked Questions

What is the purpose of a tube insert stiffener?

A machined brass sleeve pushed into a soft plastic tube end before compression fitting assembly. It stops the wall collapsing under nut and ferrule torque – without one, nylon or PU tubing can deform, leak, or blow out.

Do I need an insert for metal tubing such as copper or steel?

No. Metal tubes have enough wall rigidity for ferrule compression. Inserts are for soft tubing – nylon, PU, PTFE, TPR – and in a metal tube one can stop the ferrule biting correctly.

How do I choose the correct insert size?

Match insert to tube: a 6 x 4 mm tube takes the 6 x 4 mm insert, sliding in with a light press fit – not loose, not tight enough to split the wall. When in doubt, measure the tube ID.

Can I reuse a brass insert after disassembly?

Only if completely undamaged. Scoring, deformation, or corrosion compromises the press fit; a new insert is cheap insurance.

What happens if I skip the insert in a nylon tube?

The ferrule crushes the wall inward: the bore ovalizes, sealing fails, flow is restricted, and vibration can work the tube loose until blow-out. Always use inserts with PA, PU, PTFE, and TPR in compression fittings.

Are these inserts compatible with push-in fittings?

No. Push-in fittings grip the tube OD with a collet and O-ring – a different principle. An insert blocks the collet grip and damages the seal. Compression fittings only.

What is the difference between the 5, 6, and 15 mm inserts?

Different flow needs: 5 x 3 mm for micro-lubrication, 6 x 4 mm for standard industrial systems (most common), 15 x 12 mm for main distribution lines. Same CDA 360 brass; different wall thickness and lengths.

Can I order custom lengths or special materials?

Yes – non-standard lengths to match fitting depths, and stainless steel 316 where brass is incompatible (marine, chemical). Send your specification for quotation and lead time.

Why is the working pressure rated at 300 PSI and not higher?

The rating covers the whole joint, not the brass alone: the soft tube and the compression seal are the limiting factors, so 300 PSI (21 bar) is a conservative assembly rating for typical lubrication duty.

How do I verify the insert is properly seated?

The insert face must sit flush with the tube end (±0.5 mm). Protruding, the ferrule seats on the insert and will not seal; too deep, the unsupported tube can collapse. Sight the end and push gently against a flat surface to confirm no shift.