injection lubrication system png
Single Injector

DLX Single Lubrication Injector — Positive Displacement Oil Metering

The DLX single lubrication injector (single-DLX series) is a pressurized positive-displacement injector for cyclic oil central lubrication. When system pressure rises, the injector discharges a fixed predetermined volume; when pressure relieves, it refills from the main supply line.

Designed for volumetric periodic lubrication at approximately 1.75–3.5 MPa (17.5–35 bar) working pressure with high distribution accuracy. Install near the application point on 4 mm secondary tubing with standard compression fittings and junctions.

Discharge range: 0.025 · 0.06 · 0.1 · 0.2 · 0.3 · 0.4 · 0.5 ml/cycle (model suffix). Oil viscosity: ISO #100 – #6500. Seals: Viton.

System context: positive injector lubrication systems · single line systems · injection lubrication system.

Discharge (ml/cyc)025061020304050
Method of indication0.0250.060.10.20.30.40.5

For instance:
34000-20——34000 is product P.N., 20 is discharge indicating 0.2ml/injection; 34000-20T—-Indicating 34000-20 with adaptors and compression sleeve.

How the DLX Single Injector Works

 

  1. Pressure on — main line pressure exceeds injector start pressure (~8–12 kgf/cm² class).
  2. Metering piston strokes — exact dose (per suffix) discharges to bearing.
  3. Pressure off — pump stops or relief opens; injector recharges from supply.
  4. Next cycle — repeats for periodic film renewal at the point.

DLX injectors are for cyclic oil systems only and must be installed in the correct flow direction (check arrow on body).

Part Numbering (34000 Series Example)

SuffixDischarge (ml/cyc)Example P/N
0250.02534000-25
060.0634000-06
100.1034000-10
200.2034000-20
300.3034000-30
400.4034000-40
500.5034000-50

34000-20T = 34000-20 with adaptors and compression sleeve included.

Operating Limits

ParameterTypical value
Opening / start pressure~8–12 kgf/cm²
Operating pressure~30–35 kgf/cm²
Oil viscosity#100 – #6500
Seal materialViton
System pressure class1.75–3.5 MPa circuits

DLX Single vs Other Injectors on IsoHiTech

InjectorDischargeLubricantPage
DLX single0.025–0.5 ml/cycOil #100–6500This page
ZEM0.06–1.5 ml/cycOil or soft greasePDI hub
SL1 / BLGrease dosesNLGI to #2PDI hub
SSV progressive0.17–0.25 ml/cyc per outletGrease/oil blockLincoln SSV

Selection Guide

  1. Calculate required ml/cycle at bearing from OEM manual or trial.
  2. Choose suffix with equal or slightly higher dose — do not oversize more than one step without testing.
  3. Confirm oil viscosity at operating temperature falls in #100–6500 range.
  4. Verify pump can reach 30–35 kgf/cm² at farthest injector (line losses).
  5. Plumb with 4 mm nylon, M8 straight couplings, clips.

 

Recommended Pump Pairings

 

 

Installation & Commissioning

 

  • Mount injector close to bearing — minimize secondary line length.
  • Install with flow arrow toward bearing.
  • Prime line before connecting to injector inlet.
  • Run 3–5 cycles; confirm visible oil wetting at point.
  • Record P/N suffix on machine lubrication chart.

 

Troubleshooting

 

SymptomCauseAction
No dischargeReversed install, blocked orificeCheck arrow; clean or replace
Too much oilWrong suffix, stuck pistonDownsize suffix; replace injector
Slow refillRestricted supply lineUpsize 4 mm run; shorten length
Leak at M8 portDamaged Viton sealRebuild kit or new injector

Compare architectures: PDI vs single-line. Quote: contact IsoHiTech.

Before you buy: read our grease fitting types guide.

What is a single lubrication injector (DLX)?

A positive-displacement oil injector that meters a fixed volume each pressure cycle for cyclic central lubrication.

What oil viscosity range is supported?

Typically ISO #100 through #6500 depending on temperature and cycle time.

What is the operating working pressure?

About 30–35 kgf/cm² operating with 8–12 kgf/cm² opening pressure on standard DLX models.

How do I read the part number?

Example 34000-20 = base body with 0.2 ml/cycle. Suffix T includes adaptors and compression sleeve.

Can DLX injectors use grease?

DLX single series is for oil PDI. Soft grease uses ZEM/SL1/BL on the PDI systems page.

How does DLX differ from a single-line restrictor?

Restrictors pass flow continuously by orifice size; DLX meters a fixed shot per cycle when pressure builds.

What tubing and fittings pair with DLX injectors?

4 mm secondary nylon, standard junctions, M8 straight couplings, compression sleeves.

What is the working process in one sentence?

Pressure on → dose out → pressure off → refill → repeat on timer or machine interlock.

 

Send Your Inquiry Today